Categories

How to connect a bituminous membrane to a lead roof outlet?

Base of the accessoryUse of a primer
GalvanizedYes
LacqueredNo
PlasticConsult the accessory manufacturer
Lead Yes, see directive below

Tip!

  • To apply primer to accessories, use IKO pro Bitumen Primer SR Spray, available in a 500 ml aerosol can.
  • Lead roof drains are often coated in grease and must be properly prepared:
  1. Gently flame the lead flange of the drainage system—not too intense, just enough for the grease to melt and run off the surface.
  2. Wipe the drain with a non-synthetic cloth (a synthetic one would melt).
  3. Scrub using a wire brush.
  4. Lightly flame again to eliminate any remaining residues.
  5. Apply a thin layer of IKO pro Bitumen Primer SR.
  6. If using an APP roofing membrane, check the adhesion more thoroughly by briefly flame-welding and then lifting the membrane to verify bonding.
  7. Finally, fully torch the underside of the roofing membrane and press it onto the lead flange.